Model No. |
Features |
Topr (°C) |
Operating supply voltage
(V) |
Electro-optical characteristics |
Dissipation current (mA) |
Detection concentration µg/m3 (TYP.) |
Sensitivity |
Output |
GP2Y1010AU0F |
•Built-in infrared emitting diode, photodiode
and signal processing circuit •Compact,
single-shot detection of house dust •Output:
Analog voltage |
–10 to +65 |
4.5 to 5.5 |
TYP. 11 |
0 to 600 |
0.5±0.15 V/ (0.1 mg/m3) Precision ±30% |
Analog voltage |
GP2Y1014AU0F |
•High sensitivity •Built-in infrared emitting
diode, photodiode and signal processing
circuit •Compact, single-shot detection of
house dust •Output: Analog voltage |
4.5 to 5.5 |
TYP. 11 |
0 to 240 |
0.5±0.075 V/ (0.1 mg/m3) Precision ±15% |
Analog voltage |
GP2Y1023AU0F |
•High sensitivity •Built-in microcomputer
•Built-in infrared emitting diode, photodiode
and signal processing circuit •Compact,
single-shot detection of house dust •Output:
Digital signal output (PWM) |
4.75 to 5.25 |
TYP. 15 |
0 to 240 |
1.4±0.21 ms/ (0.1 mg/m3) Precision ±15% |
Digital signal (PWM) Temperature correction
Averaging |
GP2Y1026AU0F |
•High sensitivity •Built-in LED pulse drive
circuit •Built-in microcomputer, Dust
conventration is converted to Uart signal
output. No need for offset correction nor
averaging in set •Built-in Temperature
Correction |
4.75 to 5.25 |
TYP. 15 |
0 to 1000 |
0.35±0.06 V/ (0.1 mg/m3) Precision ±15% |
Digital signal (UART) Temperature correction
Averaging |
★GP2Y1030AU0F |
•Built-in infrared emitting diode, photodiode
and signal processing circuit •Built-in
microcomputer •Sensing can discriminate between
PM2.5 and PM10 •Internal cleaning possible |
3 to 5.5 |
TYP. 25 |
0 to 500 |
Precision ±15% |
Digital signal (UART) |